Ruud Part Subpage

Ruud Thermocouple — Standing Pilot Diagnosis

Behind most pilot-won't-stay-lit faults on Ruud standing pilot units. DIY-replaceable.

Updated May 2026 · Ruud Water Heaters

On Ruud standing-pilot gas units, the thermocouple senses pilot flame and keeps gas valve open.

Symptoms

  • Pilot lights but goes out when releasing gas knob
  • Pilot stays lit briefly then goes out
  • Pilot flame weak or yellow

DIY replacement

  1. Gas knob to "Off"; wait 5 minutes
  2. Remove burner cover
  3. Disconnect thermocouple lead from gas valve
  4. Remove from pilot bracket
  5. Install new — tip in pilot flame envelope
  6. Connect to gas valve (finger-tight + quarter-turn)
  7. Restore gas; light pilot; hold knob 60 seconds

Cost

  • Universal: $10-20
  • OEM Ruud/Rheem: $15-25

Bottom line

Common Ruud gas part. $15-25 + 45-min DIY.