Code 111 = Ignition failure / no flame. The highest-volume Takagi error code.
Diagnostic sequence
1. Gas supply
- Confirm gas valve at unit is fully open
- Test another gas appliance
- Check propane tank level if LP
2. Air in gas line
If gas was recently turned off, purge by running another appliance for 5-10 min.
3. Gas pressure
Takagi needs 4" WC NG / 10" WC propane minimum. Undersized gas line is the #1 chronic cause.
4. Flame rod (#1 hardware cause)
Cleaning resolves about 40% of chronic Code 111 cases. See flame rod.
5. Igniter
Direct spark igniter wears out. Check for spark in a dark room. See igniter.
6. Gas valve
Stuck-closed solenoid. Dealer-only replacement.
Reset
- Address suspected cause
- Press On/Off on controller
- If code returns, escalate
Bottom line
Top-down diagnostic. Flame rod cleaning is free and resolves a meaningful fraction.