Takagi Install Guide

Takagi Water Heater Installation Guide — Step by Step

Install requirements for Takagi T-H3, T-D2, T-K, T-KJr, T-T commercial cascade.

Updated May 2026 · Takagi Water Heaters

Takagi install requirements are similar to other tankless brands. T-T commercial cascade adds the multi-unit complexity.

Gas line sizing

ModelBTUMin gas line
T-KJr2 (140k)140k½" to 30 ft / ¾" over 30 ft
T-H1 (120k)120k½" to 30 ft / ¾" over 30 ft
T-H3J (140k)140k¾" required
T-K4 (190k)190k¾" required
T-M50 (175k)175k¾" required
T-H3, T-D2 (199k)199k¾" required (1" over 50 ft)
T-T1, T-T2 (199k)199k¾" or 1" depending on length
T-T cascade (per unit)see manifold sizing1¼" or 1½" common to manifold

Venting

  • Condensing (T-H3, T-D2, T-T condensing): 2" or 3" Schedule 40 PVC. Up to 100 ft equivalent length
  • Non-condensing (T-K, T-KJr, T-H1): stainless Category III venting
  • Outdoor variants: no venting required

Condensate drainage (condensing models)

  • Trap at unit outlet (Takagi includes)
  • PVC drain line to floor drain or condensate pump
  • Neutralizer if discharging to iron pipe or septic
  • Insulate or heat-trace drain through unconditioned spaces

Water softener

Required above 11 grains per gallon hardness for warranty.

T-T commercial cascade specifics

For cascade installs up to 6 units:

  • Cascade controller (Takagi-supplied)
  • Daisy-chain wiring between units
  • Manifold piping (gas, water in/out, condensate)
  • Isolation valves per unit
  • Common-vent design

Use a Takagi/AO Smith-trained commercial installer.

Outdoor unit freeze protection

Outdoor variants (T-H3-OS, T-D2-OS, T-K4-OS, T-KJr2-OS) include freeze protection — but require 120V power to operate. In cold climates with potential multi-day power outages, install a battery backup or generator transfer switch for the heater circuit.

Commissioning

  1. Purge air from gas line
  2. Open isolation valves
  3. Power on; verify display
  4. Set temperature (120°F default)
  5. For condensing: verify condensate flowing
  6. Register warranty

Permits

Required in most US jurisdictions.

Bottom line

Standard Takagi installs are within range of competent plumbers. T-T cascade requires Takagi/AO Smith-trained commercial installer.