Lochinvar Error Codes

Lochinvar Water Heater Error Codes — Diagnostic Reference

Numeric fault codes (E02, E04, E09, E12, E29, E33) for NOBLE, KNIGHT, ARMOR, and condensing commercial.

Updated May 2026 · Lochinvar Water Heaters

Lochinvar combi boilers and condensing commercial water heaters display numeric fault codes on the control panel. Code prefixes:

  • E-codes — locked-out fault; manual reset typically required
  • F-codes — soft fault; auto-clears when condition resolves
  • blocking — temporary condition; resumes when satisfied

Common codes

CodeMeaningAction
E02 / E03Low water pressure / empty systemRe-pressurize to 12-15 PSI cold; bleed air
E04Gas valve / ignition failureGas supply, igniter, flame sensor, gas pressure
E09Fan / blower failureBlower motor, capacitor, wiring, control board
E12Supply temperature sensorNTC sensor resistance test; replace if out of spec
E29High-limit lockoutOverheating; check flow, sensors, control settings
E33DHW sensor (combi only)DHW NTC sensor open/shorted; replace

How to read

  1. Display shows the active code on the LCD or LED screen
  2. Press Menu or Info button to see fault history (last 10 events)
  3. Code persists until manual reset (E-codes) or condition clears (F-codes)

How to reset

  • Front-panel reset: press and hold the Reset button 5 seconds
  • Power cycle: breaker off 30 seconds for stubborn locks
  • Don\'t repeatedly reset without diagnosing — repeated locks indicate persistent fault

Bottom line

Lochinvar fault codes are diagnostic — they tell the contractor where to look. Most resolve with annual service procedures (clear condensate trap, verify sensor resistance, gas pressure). Persistent locks need contractor diagnosis with combustion analyzer and manometer.