Rinnai Install Guide

Rinnai Water Heater Installation Guide — Step by Step

What a proper Rinnai tankless install requires — gas line sizing, venting, condensate drain, water softener, and commissioning.

Updated May 2026 · Rinnai Water Heaters

A Rinnai tankless install is more involved than a tank-to-tank swap. Skipping any item below voids the warranty and creates downstream problems that Rinnai support sees daily.

Gas line sizing

The #1 install mistake: undersized gas line. A 199 kBTU Sensei or RL94 needs ¾" black iron all the way back to the meter in most homes. ½" line will hold 5" WC at idle but drop below 4" WC under fire, throwing Code 11 or short-cycling. Have a plumber do a gas pressure test under full load; this is non-negotiable.

ModelBTUMin gas line (back to meter)
V53, V65120-150 kBTU½" up to 30 ft / ¾" over 30 ft
V75, V94180-199 kBTU¾" required
RL75, RL94180-199 kBTU¾" required
RU98, RU130180-199 kBTU¾" required
RU150-RU199, RX130-RX199, RUR199199 kBTU¾" required

Venting

  • Condensing (Sensei, Sensei RX, RUC, RSC): 2" or 3" Schedule 40 PVC / CPVC concentric or two-pipe up to 65 ft equivalent length. Use Rinnai-approved manufacturers (IPEX, Heat-Fab)
  • Non-condensing (RL, V): Rinnai-specific stainless Category III venting (not the same as B-vent — do not mix). 4" diameter typical.
  • Outdoor (V94eN, V53DeN, V65iP): no venting; cabinet is weather-sealed and vents directly to the exterior

Condensate drainage (condensing models only)

Condensing tankless units produce 1-2 gallons of acidic condensate per day. Required setup:

  • Condensate trap at the unit outlet (Rinnai includes this)
  • PVC drain line to floor drain, sink trap, or condensate pump
  • If running into iron drain pipe or septic, neutralizer is required (pH 3-5 condensate eats iron)

Water softener / scale filter

If incoming hardness exceeds 11 grains per gallon, Rinnai requires either a softener or scale filter — otherwise the warranty doesn't apply to the heat exchanger. Even at 7-11 gpg, soft water dramatically extends time between flushes.

Electrical

Standard 120V 15A circuit. Sensei RX and RUR units with built-in pump draw slightly higher peak amperage when the pump runs — still fine on 15A. Dedicated circuit recommended but not required.

Commissioning

  1. Purge air from gas line
  2. Open inlet/outlet isolation valves
  3. Open hot tap downstream to verify water flow
  4. Power on; verify display
  5. Set temperature (120°F default)
  6. If condensing: verify condensate drain flowing
  7. If recirc: program Circ-Logic schedule
  8. Pair to ControlR app
  9. Register warranty

Permits

Most US jurisdictions require a permit and inspection for tankless install — gas line, venting, and condensate disposal are all inspected. Skipping the permit voids the warranty in some states and triggers insurance issues if there's ever a gas leak.

Bottom line

The "tankless install was a nightmare" Reddit threads almost always trace to an installer who did a tank-to-tank swap without re-sizing the gas line, re-piping for proper venting, or installing a condensate trap. A Rinnai-trained installer ($300-500 more upfront) saves these problems. See our dealers hub for finding one.