Reliance Maintenance

Reliance Water Heater Element Testing — Multimeter Procedure

Multimeter ohms test for upper and lower elements on Reliance Standard, Extended, and Mini-Tank electric models.

Updated May 2026 · Reliance Water Heaters

If a Reliance 6-EORS, 9-EORS, or HPHE backup element isn\'t heating, the most likely failure is a burned-out element. A 5-minute ohms test confirms it before you order a replacement.

What you need

  • Multimeter (digital, ohms function)
  • Phillips screwdriver
  • Voltage tester (verify power is OFF)

Procedure

  1. Turn off power. Flip 240V breaker. Use a voltage tester on the element terminals to confirm
  2. Remove access cover. Phillips screws on upper and lower side panels
  3. Fold back insulation and remove the plastic safety cover
  4. Disconnect one element lead (leaves the element isolated for testing)
  5. Set multimeter to Ω (resistance). 200Ω range or auto-range
  6. Touch probes to the two element screws. Read resistance

Interpreting the reading

Element wattageHealthy readingFailed
3500W16-18 ΩOpen (OL) or short (0)
4500W (most common)10-16 ΩOpen (OL) or short (0)
5500W9-11 ΩOpen (OL) or short (0)
1500W mini-tank38-42 ΩOpen (OL) or short (0)

Element-to-ground test

With multimeter still in Ω mode, touch one probe to an element screw and the other to the tank shell. Should read OL (open). Continuity to ground = element shorted to sheath → replace and verify the breaker isn\'t tripped by a wet element.

Common failure patterns

  • Lukewarm water, slow recovery: lower element failed. Upper continues to heat the top section
  • No hot water at all: upper element failed (upper is the primary)
  • Element shorts to ground: breaker trips immediately on reset — wet or cracked element
  • Element appears OK but no heat: check upper thermostat (test continuity) before replacing element

Element replacement

If failed:

  1. Drain tank to a level below the bad element (lower element = full drain; upper = drain ~½ tank)
  2. Disconnect both leads
  3. Unscrew element with element wrench (1-½" socket)
  4. Install new element with new gasket; torque to spec (~50 ft-lb on screw-in; quarter-turn past gasket compression on flange)
  5. Refill tank — open hot tap to vent air
  6. Restore power only after tank is full

See Reliance heating element parts. AO Smith family elements are universally interchangeable across State, AO Smith Signature, Whirlpool, and Reliance at equivalent wattages.

Bottom line

Healthy 4500W element reads 10-16 Ω. Open or short = replace. Always test before ordering parts — bad thermostat or tripped ECO causes similar symptoms.